Daten auslesen:




ADSL counters:
Local_RSI_Counter: count of near-end Reed-Solomon forward error corrections for the interleaved data stream
Local_RSF_Counter: count of near-end Reed-Solomon forward error corrections for the fast data stream
Local_CRSI_Counter: count of CRC near-end anomalies for the interleaved data stream
Local_CRSF_Counter: count of CRC near-end anomalies for the fast data stream
Local_SEF_Couner: count of near-end severely errored frame defects
Local_LOS_Counter: count of near-end loss of signal defects
Remote_RSI_Counter: count of far-end Reed-Solomon forward error corrections for the interleaved data stream
Remote_RSF_Counter: count of far-end Reed-Solomon forward error corrections for the fast data stream
Remote_CRSI_Counter: count of CRC far-end anomalies for the interleaved data stream
Remote_CRSF_Counter: count of CRC far-end anomalies for the fast data stream
Remote_SEF_Counter: count of far-end severely errored frame defects
Remote_LOS_Counter: count of far-end loss of signal defect

ATM counters:
Local_NCDI_Counter: count of near-end no cell delineation for the interleaved data stream
Local_NCDF_Counter: count of near-end no cell delineation for the fast data stream
Local_OCDI_Counter: count of near-end out of cell delineation for the interleaved data stream
Local_OCDF_Counter: count of near-end out of cell delineation for the fast data stream
Local_HECI_Counter: near-end header error check counter for the interleaved data stream
Local_HECF_Counter: near-end header error check counter for the fast data stream
Remote_NCDI_Counter: count of far-end no cell delineation for the interleaved data stream
Remote_NCDF_Counter: count of far-end no cell delineation for the fast data stream
Remote_HECI_Counter: far-end header error check counter for the interleaved data stream
Remote_HECF_Counter: far-end header error check counter for the fast data stream


ADSL failures:
Overall_Failure: Non-zero value if any failures have occurred
Local_Sef_Failure: count of near-end severely error frames
Local_Los_Failure: count of near-end loss of signal
Remote_Pow_Failure: count of far-end dying gasp frames
Remote_Sef_Failure: count of far-end severely error framed
Remote_Los_Failure: count of far-end loss of signal

ATM failures:
Local_ncdI_Failure: count of near-end no cell delineation for the interleaved data stream
Local_ncdF_Failure: count of near-end no cell delineation for the fast data stream
Local_lcdI_Failure: count of near-end loss of cell delineation for the interleaved data stream
Local_lcdF_failure: count of near-end loss of cell delineation for the fast data stream
Remote_ncdI_Failure: count of far-end no cell delineation for the interleaved data stream
Remote_ncdF_Failure: count of far-end no cell delineation for the fast data stream
Remote_lcdI_Failure: count of far-end loss of cell delineation for the interleaved data stream
Remote_lcdF_Failure: count of far-end loss of cell delineation for the fast data stream