| Local Noise Margin | = Signal-Rausch-Abstand im Downstream-Frequenzbereich in dB |
| Local Attenuation* | = Leitungsdämpfung im Downstream-Frequenzbereich (276-1104kHz) in dB |
| Remote Attenuation** | = Leitungsdämpfung im Upstream-Frequenzbereich (138-276kHz) in dB |
| Local Tx Power | = Sendeleistung vom Xavi in dBm |
|
* Dämpfungen über 63db werden mit 63dB angezeigt. ** Dämpfungen über 31db werden mit 31dB angezeigt. |

|
ADSL counters: Local_RSI_Counter: count of near-end Reed-Solomon forward error corrections for the interleaved data stream Local_RSF_Counter: count of near-end Reed-Solomon forward error corrections for the fast data stream Local_CRSI_Counter: count of CRC near-end anomalies for the interleaved data stream Local_CRSF_Counter: count of CRC near-end anomalies for the fast data stream Local_SEF_Couner: count of near-end severely errored frame defects Local_LOS_Counter: count of near-end loss of signal defects Remote_RSI_Counter: count of far-end Reed-Solomon forward error corrections for the interleaved data stream Remote_RSF_Counter: count of far-end Reed-Solomon forward error corrections for the fast data stream Remote_CRSI_Counter: count of CRC far-end anomalies for the interleaved data stream Remote_CRSF_Counter: count of CRC far-end anomalies for the fast data stream Remote_SEF_Counter: count of far-end severely errored frame defects Remote_LOS_Counter: count of far-end loss of signal defect ATM counters: Local_NCDI_Counter: count of near-end no cell delineation for the interleaved data stream Local_NCDF_Counter: count of near-end no cell delineation for the fast data stream Local_OCDI_Counter: count of near-end out of cell delineation for the interleaved data stream Local_OCDF_Counter: count of near-end out of cell delineation for the fast data stream Local_HECI_Counter: near-end header error check counter for the interleaved data stream Local_HECF_Counter: near-end header error check counter for the fast data stream Remote_NCDI_Counter: count of far-end no cell delineation for the interleaved data stream Remote_NCDF_Counter: count of far-end no cell delineation for the fast data stream Remote_HECI_Counter: far-end header error check counter for the interleaved data stream Remote_HECF_Counter: far-end header error check counter for the fast data stream |

|
ADSL failures: Overall_Failure: Non-zero value if any failures have occurred Local_Sef_Failure: count of near-end severely error frames Local_Los_Failure: count of near-end loss of signal Remote_Pow_Failure: count of far-end dying gasp frames Remote_Sef_Failure: count of far-end severely error framed Remote_Los_Failure: count of far-end loss of signal ATM failures: Local_ncdI_Failure: count of near-end no cell delineation for the interleaved data stream Local_ncdF_Failure: count of near-end no cell delineation for the fast data stream Local_lcdI_Failure: count of near-end loss of cell delineation for the interleaved data stream Local_lcdF_failure: count of near-end loss of cell delineation for the fast data stream Remote_ncdI_Failure: count of far-end no cell delineation for the interleaved data stream Remote_ncdF_Failure: count of far-end no cell delineation for the fast data stream Remote_lcdI_Failure: count of far-end loss of cell delineation for the interleaved data stream Remote_lcdF_Failure: count of far-end loss of cell delineation for the fast data stream |